The CANONSampler start-of-sip message names the motor controller driving the sampler, and some vehicles log "MAXON will go to position" instead of "ELMO will go to position". Only ELMO was matched, so sips from MAXON-equipped samplers were missed. Add SIPPERING_MAXON and a SIPPERING_MARKERS tuple, and match any marker in Sipper._parse_lines(). SIPPERING keeps its ELMO value so existing imports are unaffected. Start messages of either kind are paired with Sample/err_code messages in arrival order as before. Add tests for MAXON-only and mixed ELMO/MAXON syslogs. Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
The CANONSampler start-of-sip message names the motor controller driving the sampler, and some vehicles log "MAXON will go to position" instead of "ELMO will go to position". Only ELMO was matched, so sips from MAXON-equipped samplers were missed.
Add SIPPERING_MAXON and a SIPPERING_MARKERS tuple, and match any marker in Sipper._parse_lines(). SIPPERING keeps its ELMO value so existing imports are unaffected. Start messages of either kind are paired with Sample/err_code messages in arrival order as before.
Add tests for MAXON-only and mixed ELMO/MAXON syslogs.